Daily maintenance of the centrifuge

The centrifuge should be cut off power supply before operation and to loose the centrifuge brake, can hand try rotating drum, see any bite evil spirit.

Check whether there is any loose and on other parts of the abnormal situation.

Start: clockwise direction turning on the power supply drive (usually from static state to normal operation about 40 to 60 seconds).

Usually each device to factory shall be run idle after 3 hours, work without exception.

Material to place even as much as possible.

Shall not exceed the rated quantity must be specialist operations, capacity.

It is forbidden to machine overdrive, lest affect the service life of the machine.

After machines on, if any abnormal situation must stop inspection, repair as needed to unpick and wash.

Centrifuge when work is a high speed, so don't use your body to touch the rotary drum, in case of accident.

Mesh filter cloth should be according to the size of the solid phase particles separation material, otherwise affect the separation efficiency. Another filter cloth when installation should be filter cloth

Sealing ring embedded drum sealing groove, run into the case material.

To ensure the normal working of the centrifuge, rotating components please serviced once every six months after refueling. Work at the same time to check the bearing lubrication condition, have without wear phenomenon; The parts have wear of brake device, serious to replace; No oil leaking in the bearing bore.

Machine after use, should clean job, keep the machine clean.

Don't put the anti-corrosion type centrifuge and in the separation of high corrosive materials; Additional equipment in strict accordance with the requirements of operation and regulation, the explosion-proof type centrifuge must not used for inflammable and explosive occasions.

The "surge"

Centrifugal units of centrifuge "surge" occur often.

Refrigeration principle of centrifugal compressor is big molecular weight of refrigerant through high speed movement backlog in little space is compressed, and then through the cooling condensation.

Centrifugal chiller regulates energy by adjusting the guide of high-speed rotation Angle to adjust the compression ratio

When decreased cooling guide to do the work is reduced, compressed out of gas pressure and suction gas pressure of the compressor, resulting in gas flow of forced vibration machinery. (also known as the "surge") surge will cause the damage of the mechanical components.

关闭
用手机扫描二维码关闭
二维码